Hey guys,

I got a problem with our sql2008r2 fail-over production cluster!

after changing the NICs to use VLAN tagging (2 VLANs at one Port) the cluster validation test 
failed with the following messages:

Found duplicate physical address 68-B5-99-6F-FB-A4 on node SKRZDB06FCN1.asp.krzwan.de adapter Inter-Cluster-Network and node SKRZDB06FCN1.asp.krzwan.de adapter Client-Network.
Found duplicate physical address 68-B5-99-6F-AB-A4 on node SKRZDB06FCN2.asp.krzwan.de adapter Inter-Cluster-Network and node SKRZDB06FCN2.asp.krzwan.de adapter Client-Network.
Found duplicate physical address 68-B5-99-77-78-16 on node SKRZDB06FCN3.asp.krzwan.de adapter Inter-Cluster-Network and node SKRZDB06FCN3.asp.krzwan.de adapter Client-Network.
Found duplicate physical address 68-B5-99-75-C4-76 on node SKRZDB06FCN4.asp.krzwan.de adapter Inter-Cluster-Network and node SKRZDB06FCN4.asp.krzwan.de adapter Client-Network.

But, with vlan tagging (2 VLANs at one port) with teaming the interfaces it is actually correct that both virtual NICs use the same MAC. This is correct at layer 2 communication. 

The Cluster works fine and has no issues. 

Why does the cluster validation test fail? - Is vlan tagging not supported?

SQL Server Version: SQL Server 2008 R2 (10.50.1600) Enterprise

OS Version: Windows Server 2008 R2 Enterprise

Thank you for any reply!

Regards,

Philipp